171459 SL7-SWD
Base module;connection to SmartWire-DT
EL Number (Norway)
4137714
Base module, Color black, Aluminum color tube, Product range: SL signal towers, SmartWire-DT slave, Subrange: SmartWire-DT Signal towers, Connection technique: Blade terminal SWD4-8MF2, Mounting type: for horizontal mounting, Fitted with: Base with base adapter for slipping onto place (rapid mounting and wiring system), including cover, Tube length: 100 mm, Description: External power supply connectable (24 V DC), Configurable with SWD‐Assist (planning and ordering tool), Further technical data, see manual MN05006001Z., Number of modules: max. 5 modules, max. 0.3 A per module, For use with: SL7-L-…, SL7-BL-…, SL7-FL-…, SL7-AP-… , Connection to SmartWire-DT: yes, Standards: IEC/EN 60947-5-1, IEC degree of protection: IP66, IEC/EN 60529, Protection type UL: Type 4, 4X, 13
General specifications
Product name
Eaton Moeller® series SL7 Base module
Part no.
SL7-SWD
EAN
4015081677870
Product Length/Depth
81 millimetre
Product height
175 millimetre
Product width
81 millimetre
Product weight
0.231 kilogram
Certifications
IEC/EN 60529
UL 508
CSA-C22.2 No. 94-91
CE
IEC/EN 60947-5-1
CSA-C22.2 No. 14-10
UL 508
CSA-C22.2 No. 94-91
CE
IEC/EN 60947-5-1
CSA-C22.2 No. 14-10
Product Tradename
SL7
Product Type
Base module
Product Sub Type
None
Features & Functions
Color
Other
Fitted with:
Cover
Base adapter for slipping onto place (rapid mounting and wiring system)
Base adapter for slipping onto place (rapid mounting and wiring system)
Number of modules
Max. 5 (0.3 A per module)
Max. 10 (with base for mounting on both sides)
Max. 5 (with standard base)
Max. 10 (with base for mounting on both sides)
Max. 5 (with standard base)
General information
Connection to SmartWire-DT
Yes
Degree of protection
IP66
NEMA 13
NEMA 4X
NEMA 4
NEMA 13
NEMA 4X
NEMA 4
Mounting Method
Floor
Horizontal
Bracket
Horizontal
Bracket
Mounting position
As required
Product Category
SL signal towers
SmartWire-DT slave
SmartWire-DT slave
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27
Mechanical, According to IEC/EN 60068-2-27
Tube length
100 mm
Type
Base module
Climatic environmental conditions
Ambient operating temperature - min
-30 °C
Ambient operating temperature - max
60 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Damp heat, constant, to IEC 60068-2-78
Technical data ETIM 9.0
Low-voltage industrial components (EG000017) / Connection module for signal tower (EC001152)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Signal column element, connection module (ecl@ss13-27-37-12-32 [AKF050019])
Connection type auxiliary circuit
Spring clamp connection
Suitable for tube mounting
No
Suitable for angle mounting
Yes
Suitable for floor mounting
Yes
Colour
Other
Suitable for AS interface
No
Suitable for M12 connector
No
Suitable for IO link
No
-