General specifications
Product name
Eaton Moeller series xPole - SPBT12 Surge protection device
Part no.
SPBT12-280-3+NPE
EAN
4015081549207
Product Length/Depth
90 millimetre
Product height
69 millimetre
Product width
87.5 millimetre
Product weight
0.668 kilogram
Compliances
RoHS conform
Product Tradename
xPole - SPBT12
Product Type
Surge protection device
Product Sub Type
None
Delivery program
Application
Open areas
Residential buildings
Utility buildings
Number of poles
Four-pole
Type
Surge arrester
Technical Data - Electrical
Voltage protection level
0 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Voltage protection level (L-N)
1.5 kV
Voltage protection level (L-PE)
1.5 kV
Voltage protection level (N-PE)
100 kV
Nominal voltage at AC
280 V
Nominal voltage at DC
0 V
Continuous voltage at AC - max
280 V
Continuous voltage at DC - max
0 V
PV-voltage - max
0 V
Lightning impulse current (10/350 µs)
12.5 kA
Follow current extinguishing capability
0 kA
Signalling at the device
Optic
Specific energy (W/R)
2500 kJ/Ohm
Technical Data - Mechanical
Frame
5 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Conductor cross section (flexible, fine-strand) - max
35 mm²
Conductor cross section (solid, solid-strand) - max
25 mm²
Degree of protection
IP20
Additional information
Features
Voltage switching spark gap technology
System configuration type
Other
IT
TN
TN-S
TT
Test class
Type 1 + 2

Technical data ETIM 9.0

Earthing, lightning and surge protection (EG000021) / Combined arrester for power supply systems (EC001457)
Electric engineering, automation, process control engineering / Internal and external lightning protection / Combined SPD for energy and information technology / Energy and MSR technology (ecl@ss13-27-17-16-01 [AHE455002])
System configuration DC
No
System configuration IT
Yes
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration TT
Yes
System configuration other
Yes
Number of poles
4
Lightning impulse current (10/350 µs)
12.5 kA
Max. continuous voltage AC
280 V
Max. continuous voltage DC
0 V
Nominal voltage AC
280 V
Nominal voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
0 kV
Voltage protection level L-N
1.5 kV
Voltage protection level L-PE
1.5 kV
Voltage protection level N-PE
100 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Follow current extinguishing capability
0 kA
Specific energy (W/R)
2500 kJ/Ohm
Max. overcurrent protection device, parallel connection (fuse)
0 A
Max. overcurrent protection device, series connection (fuse)
0 A
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
5 modular spacing
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
Remote signalling
No
Signalling at the device
Optical
Test class
Type 1 + 2
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Voltage switching spark gap technology
Yes
Overcurrent protected voltage tapping
No
Degree of protection (IP)
IP20